• from
    to

Explore our range of heat pump solutions and essential components. This category includes all necessary subassemblies and parts for building and maintaining modern, efficient, and eco-friendly heating systems.

Heat Pumps Subassemblies

Condensing Low Loss Header SHE 135kW 1 1/2" CD INOX

Condensing Low Loss Header SHE 135kW 1 1/2" CD INOX
Condensing Low Loss Header SHE 135kW 1 1/2" CD INOX

Condensing Low Loss Header STAINLESS STEEL (INOX) - 135kW 1 1/2" (female threaded tappings) insulated

Availability: Low stock

Dispatched within: 48 hours

Price:

£295.00

pcs

Condensing Low Loss Header SHE 90 1 1/4" CD INOX

Condensing Low Loss Header SHE 90 1 1/4" CD INOX
Condensing Low Loss Header SHE 90 1 1/4" CD INOX

Condensing Low Loss Header STAINLESS STEEL - 90kW 1 1/4" (female threaded tappings) insulated

Availability: Low stock

Dispatched within: 48 hours

Price:

£275.00

pcs

Distribution Low Loss Header SKE 35kW, 1" insulated

Distribution Low Loss Header SKE 35kW, 1" insulated
Distribution Low Loss Header SKE 35kW, 1" insulated

Condensing Distribution Low Loss Header 1" 35kW  - HORIZONTAL/VERTICAL

This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.

Availability: In stock

Dispatched within: 48 hours

Price:

£225.00

pcs

Distribution Low Loss Header SKE 40kW, 1" insulated

Distribution Low Loss Header SKE 40kW, 1" insulated
Distribution Low Loss Header SKE 40kW, 1" insulated

 Distribution Low Loss Header 1" 40kW  - HORIZONTAL/VERTICAL

This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.

 

Hydraulic Coupling-Collectors SKE

SKE coupling-collectors are available in standard and Condens (DC) versions. The Condens version is equipped with a patented flow director. The Inox director maintains high efficiency of condensing boilers or heat pumps. The Inox director allows for alternating connection of pump groups with a spacing of 125mm. A version for heating circuits DN32 is also available. The standard version (2D+) offers limited possibilities for connecting pump groups. Universal construction (adaptation kit) enables installation within a 360° range. Connection of two, three, or four (4DC) pump groups is possible. Expansion of SKE 2DC+ for an additional heating circuit (expansion kit, only DN25) is possible. SKE 2DC+ are part of ready-made sets with pump groups – Kompania and Kompania PRO. Products are insulated with EPP molds.

 

 

Availability: Plenty in stock

Dispatched within: 48 hours

Price:

£165.00

pcs

Distribution Low Loss Header SKE 55kW, 1" insulated

Distribution Low Loss Header SKE 55kW, 1" insulated
Distribution Low Loss Header SKE 55kW, 1" insulated

Condensing Distribution Low Loss Header 1" 55kW  - HORIZONTAL/VERTICAL

This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.

Availability: Plenty in stock

Dispatched within: 48 hours

Price:

£275.00

pcs

Distribution Low Loss Header SKE 70kW, 1" insulated

Distribution Low Loss Header SKE 70kW, 1" insulated
Distribution Low Loss Header SKE 70kW, 1" insulated

 Distribution Low Loss Header 1" 70kW  - HORIZONTAL/VERTICAL

This low loss header has 4 x 1" tapings on 1 side and 2 x 1 1/4" tapings on the opposite side.

 

Hydraulic Coupling-Collectors SKE

SKE coupling-collectors are available in standard and Condens (DC) versions. The Condens version is equipped with a patented flow director. The Inox director maintains high efficiency of condensing boilers or heat pumps. The Inox director allows for alternating connection of pump groups with a spacing of 125mm. A version for heating circuits DN32 is also available. The standard version (2D+) offers limited possibilities for connecting pump groups. Universal construction (adaptation kit) enables installation within a 360° range. Connection of two, three, or four (4DC) pump groups is possible. Expansion of SKE 2DC+ for an additional heating circuit (expansion kit, only DN25) is possible. SKE 2DC+ are part of ready-made sets with pump groups – Kompania and Kompania PRO. Products are insulated with EPP molds.

Availability: In stock

Dispatched within: 48 hours

Price:

£175.00

pcs

Distribution Low Loss Header SKE 90kW, 2DC+ insulated

Distribution Low Loss Header SKE 90kW, 2DC+ insulated
Distribution Low Loss Header SKE 90kW, 2DC+ insulated

Condensing Distribution Low Loss Header  90kW  - HORIZONTAL/VERTICAL

This low loss header has 4 x 1" tapings on 1 side and 2 x 1 1/4" tapings on the opposite side.

Availability: Low stock

Dispatched within: 48 hours

Price:

£299.00

pcs

Low Loss Header 100kW + 2 way insulation manifold 1 1/2"

Low Loss Header 100kW + 2 way insulation manifold 1 1/2"
Low Loss Header 100kW + 2 way insulation manifold 1 1/2"

1 1/4" 70kW Coated Low Loss Header + 2 way insulated, connecting manifold with female threaded tapings 1 1/4"

Availability: Low stock

Dispatched within: 48 hours

Price:

£409.00

pcs

Low Loss Header 100kW, 1 1/2" + 3 way insulated manifold 1 1/2" -set

Low Loss Header 100kW, 1 1/2" + 3 way insulated manifold 1 1/2" -set
Low Loss Header 100kW, 1 1/2" + 3 way insulated manifold 1 1/2" -set

1 1/2" 100kW Coated Low Loss Header + 3 way insulated, connecting manifold with female threaded tapings.

Availability: Low stock

Dispatched within: 48 hours

Price:

£495.00

pcs

Low Loss Header 100kW, 1 1/2" insulated

Low Loss Header 100kW, 1 1/2" insulated
Low Loss Header 100kW, 1 1/2" insulated

 

ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements. 

Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.

Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.

 

The Low-Loss Header, also known as a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system for medium to high-power applications (25 kW and above, suitable for an average house). It is used in systems with multiple boilers and various heating circuits, such as floor heating, radiators, and hot utility water. The LLH eliminates the need for manual balancing of pump flows by automatically separating flows and allowing them to operate independently. Its construction includes a desilter and air vent, adding functions of system cleaning and air removal, while also protecting the boiler from low-temperature corrosion of returning water.

Operational Modes:

  1. When heat demand equals boiler output, the system balances naturally.
  2. If demand is less than boiler output (e.g., thermostat valves closed), part of the heat returns from the LLH, signaling the boiler to reduce or switch off.
  3. If demand exceeds boiler output, increased pump suction signals the boiler to boost power.

Features of the Low Loss Header SHE 1 1/2":

  • Max flow: 5.7 m³/h
  • Max power: 100 kW
  • Connectors: 4 x 1 1/2" male threads
  • Nominal pressure: 10 bar
  • Max temperature: 110°C
  • Capacity: 2.7 liters
  • Vent and drain valves included

Advantages for investors:

  • Up to 30% longer boiler service life due to protection from low return water temperature
  • Enhanced operational comfort through system desiltering and aeration
  • Up to 30% longer pump service life
  • Faster boiler response
  • Cost-effective: up to 50% cheaper than 3- or 4-way valves

Advantages for installers:

  • No system regulation needed due to automatic flow separation
  • Fewer claims caused by air locking or system inefficiencies

Variants:

  • SHE (LLH): Power ranging from 40 to 420 kW
  • SHE-OC: Insulated with PUR foam and leatherette, power from 40 to 115 kW (larger units up to 420 kW can be insulated upon request)
  • SHE-SP: Stainless steel with a replaceable air separator, power from 25 to 209 kW

Customer satisfaction is achieved through reliable, efficient system performance and reduced maintenance.

Availability: Plenty in stock

Dispatched within: 3 days

Price:

£240.00

pcs

Low Loss Header 115kW, 2" + 2 way insulation manifold 2"

Low Loss Header 115kW, 2" + 2 way insulation manifold 2"
Low Loss Header 115kW, 2" + 2 way insulation manifold 2"

2" 115kW Coated Low Loss Header + 2 way insulated, connecting manifold with female threaded tapings 2"

Availability: Low stock

Dispatched within: 48 hours

Price:

£470.00

pcs

Low Loss Header 115kW, 2" insulated

Low Loss Header 115kW, 2" insulated
Low Loss Header 115kW, 2" insulated

 

ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements. 

Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.

Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.

The Low-Loss Header, also known as a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium- to high-power setups (from 25 kW, ideal for an average house). It accommodates one or multiple boilers and various heating circuits like floor heating, radiators, or hot utility water. The LLH automatically manages flow separation, eliminating the need to manually balance pump flows. Its construction includes a desilter and air vent, which provide additional system cleaning and air removal functions. It also helps protect the boiler from low-temperature corrosion of the return water.

 

Operational Modes:

  1. When the heat demand equals the boiler's capacity, the system operates normally.
  2. If the demand is less than the boiler output (e.g., thermostatic valves closed), some heat returns from the LLH, signaling the boiler to reduce or switch off.
  3. If the demand exceeds the boiler capacity, increased pump suction signals the boiler to increase output.

Features of the Low Loss Header SHE 2":

  • Max Flow: 6.6 m³/h
  • Max Power: 115 kW
  • Connectors: 4 x 2" male threads
  • Nominal Pressure: 10 bar
  • Max Temperature: 110°C
  • Capacity: 3.2 liters
  • Vent and drain valves included

Benefits for Investors:

  • Up to 30% longer boiler service life due to protection from low return water temperature
  • Increased operational comfort with system desiltering and aeration
  • Up to 30% longer pump lifespan via undisturbed operation
  • Faster boiler response
  • Cost savings of up to 50% compared to 3- or 4-way valves

Additional Benefits:

  • No need for system regulation, thanks to automatic flow separation
  • Fewer claims caused by air locking or system inefficiencies

Variants:

  • SHE – LLH: Power from 40 to 420 kW
  • SHE-OC: Insulated with Polyprene shell (up to 156 kW, larger units up to 420 kW can be insulated with ROCKWOOL upon request)

This system ensures reliable, efficient operation, reducing maintenance and increasing system lifespan.

 

Availability: Low stock

Dispatched within: 48 hours

Price:

£275.00

pcs

Low Loss Header 156kW, 2" + 2 way insulation manifold 2" set

Low Loss Header 156kW, 2" + 2 way insulation manifold 2"  set
Low Loss Header 156kW, 2" + 2 way insulation manifold 2" set

2" 156kW Coated Low Loss Header + 2 way insulated, connecting manifold with female threaded tapings 2"

Availability: Low stock

Dispatched within: 48 hours

Price:

£485.00

pcs

Low Loss Header 156kW, 2" + 3 way insulation manifold 2" -set

Low Loss Header 156kW, 2" + 3 way insulation manifold 2" -set
Low Loss Header 156kW, 2" + 3 way insulation manifold 2" -set

2" 156kW Coated Low Loss Header + 3 way, + 2 way insulated, connecting manifold with female threaded tapings.

Availability: Low stock

Dispatched within: 48 hours

Price:

£550.00

pcs

Low Loss Header 156kW, 2" insulated

Low Loss Header 156kW, 2" insulated
Low Loss Header 156kW, 2" insulated

 

ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements. 

Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.

Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.

 

The Low-Loss Header, also known as a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium to high-power systems (25 kW and above, ideal for an average house). It is used in setups with one or more boilers and various heating circuits, such as floor heating, radiators, or hot utility water. The LLH automatically manages flow separation, eliminating the need for manual balancing of pump flows. Its construction includes a desilter and air vent, offering additional benefits of system cleaning and air removal while protecting the boiler from low-temperature corrosion of the return water.

 

Operational Modes:

  1. When the heat requirement equals the boiler’s power, the system operates in balance.
  2. If the requirement is less than the boiler’s capacity (e.g., thermostatic valves are closed), some heat returns from the LLH, signaling the boiler to decrease output or switch off.
  3. If the requirement exceeds the boiler’s capacity, increased pump suction signals the boiler to produce more heat.

Features of the Low Loss Header SHE 2”:

  • Max flow: 7.4 m³/h
  • Max power: 156 kW
  • Connectors: 4 x 2" male threads
  • Nominal pressure: 10 bar
  • Max temperature: 110°C
  • Capacity: 4 liters (or 1 liter in some configurations)
  • Vent and drain valves included

Advantages for investors:

  • Up to 30% longer boiler service life through protection from low return water temperatures
  • Enhanced operational comfort via system desiltering and aeration
  • Up to 30% longer pump service life due to smooth, undisturbed operation
  • Faster boiler reactions to changing demands
  • Cost savings of up to 50% compared to traditional 3- or 4-way valves

Advantages for installers:

  • No need for complex system regulation, thanks to automatic flow management
  • Reduced claims caused by air locking or improper operation

Variants Available:

  • SHE – LLH: Power range from 40 to 420 kW
  • SHE-OC: Insulated with polyprene shell, power from 40 to 156 kW (up to 420 kW can be insulated with ROCKWOOL upon request)

Customer satisfaction benefits from reliable, efficient heating operation with less maintenance and fewer issues.

 

Availability: In stock

Dispatched within: 48 hours

Price:

£299.00

pcs

Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 70 2D+

Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 70 2D+
Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 70 2D+

Distribution Low Loss Header  70kW  - HORIZONTAL/VERTICAL

This low loss header has 6 x 1" tapings  and 2 x 1 1/4" tapings.

 

Hydraulic Coupling-Collectors SKE

SKE coupling-collectors are available in standard and Condens (DC) versions. The Condens version is equipped with a patented flow director. The Inox director maintains high efficiency of condensing boilers or heat pumps. The Inox director allows for alternating connection of pump groups with a spacing of 125mm. A version for heating circuits DN32 is also available. The standard version (2D+) offers limited possibilities for connecting pump groups. Universal construction (adaptation kit) enables installation within a 360° range. Connection of two, three, or four (4DC) pump groups is possible. Expansion of SKE 2DC+ for an additional heating circuit (expansion kit, only DN25) is possible. SKE 2DC+ are part of ready-made sets with pump groups – Kompania and Kompania PRO. Products are insulated with EPP molds.

Availability: Plenty in stock

Dispatched within: 48 hours

Price:

£240.00

pcs

Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 90 3DC

Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 90 3DC
Low Loss Header 2 x 1 1/4" tapings and 6 x 1" tapings SKE 90 3DC

Condensing Distribution Low Loss Header  90kW  - HORIZONTAL/VERTICAL

This low loss header has 6 x 1" tapings on 1 side and 2 x 1 1/4" tapings on the opposite side.

Availability: Low stock

Dispatched within: 48 hours

Price:

£320.00

pcs

Low Loss Header 2 x 1" tapings and 6 x 1" tapings SKE 40 2d+

Low Loss Header 2 x 1" tapings and 6 x 1" tapings SKE 40 2d+
Low Loss Header 2 x 1" tapings and 6 x 1" tapings SKE 40 2d+

Condensing Distribution Low Loss Header  40kW  - HORIZONTAL/VERTICAL

This low loss header has 6 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.

Availability: Plenty in stock

Dispatched within: 48 hours

Price:

£230.00

pcs
up
Shop is in view mode
View full version of the site
Sklep internetowy Shoper.pl