Vendor
Price
-
from
to
Low Loss Header, Multi-tapings Low Loss Headers, Distribution Low Loss Headers - Page 3
Low Loss Header SHE 135kW, 4 x 1 1/2" insulated CONDENSING
Low Loss Header SHE 135kW, 4 x 1 1/2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 150kW, 4 x 2" insulated CONDENSING
Low Loss Header SHE 150kW, 4 x 2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 210kW, 4 x 2" insulated CONDENSING
Low Loss Header SHE 210kW, 4 x 2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 35kW, 1" insulated CONDENSING
Low Loss Header SHE 35kW, 4 x 1" male threaded tapings
Availability: Low stock
Dispatched within: 5 days
Low Loss Header SHE 55kW, 4 x 1" insulated CONDENSING
Low Loss Header SHE 55kW, 4 x 1" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 90kW, 4 x 1 1/4" insulated CONDENSING
Low Loss Header SHE 90kW, 4 x 1 1/4" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header up to 100kW, 2K PRO - 1 1/2" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header up to 156kW, 2K PRO - 2" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header, flanged 225kW, 2.5" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Low-Loss Header, also called a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium- to high-power setups (from 25 kW up to 420 kW). It’s used with one or more boilers and supports various heating circuits like floor heating, radiators, and hot utility water.
Key Functions and Benefits:
- Flow Separation: Automatically divides flow, allowing boiler and system to operate independently without manual balancing.
- Additional Features: Equipped with a desilter and air vent, which aid in system cleaning and removing air, enhancing efficiency.
- Protection: Prevents low-temperature corrosion by maintaining appropriate return water temperatures.
Operational Modes:
- Heat demand = boiler output: System operates normally.
- Heat demand < boiler output (e.g., thermostatic valves closed): Part of the heat returns, signaling the boiler to decrease or switch off.
- Heat demand > boiler output: Pump suction increases, prompting the boiler to produce more heat.
Equipment Details:
Low Loss Header SHE 2.5" Flanges
- Max flow: 24 m³/h
- Max power: 420 kW
- Connectors: 4 x 2.5" flanges
- Nominal pressure: 10 bar
- Max temperature: 110°C
- Capacity: 19.7 liters
Advantages for Investors:
- Up to 30% longer boiler lifespan due to protection from low return water temperatures
- Increased comfort through system desiltering and aeration
- Up to 30% longer pump operation life
- Faster boiler response
- Up to 50% cost savings versus 3- or 4-way valves
- No system regulation needed
- Fewer system claims caused by air locking or improper operation
Variants Available:
- SHE – LLH: Power range from 40 to 750 kW
- SHE-OC: Insulated with PUR foam and leatherette; power from 40 to 156 kW (larger units up to 750 kW can be insulated with ROCKWOOL if requested)
- Summary:
This hydraulic balancer ensures efficient, reliable operation of heating systems, reduces maintenance, and prolongs equipment lifespan—offering long-term savings and peace of mind for system owners.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header, flanged 420kW, 3" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
.Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Low-Loss Header, also known as a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium to high-power systems (25 kW and above, ideal for an average house). It is used in setups with one or more boilers and various heating circuits, such as floor heating, radiators, or hot utility water. The LLH automatically manages flow separation, eliminating the need for manual balancing of pump flows. Its construction includes a desilter and air vent, offering additional benefits of system cleaning and air removal while protecting the boiler from low-temperature corrosion of the return water.
Operational Modes:
- When the heat requirement equals the boiler’s power, the system operates in balance.
- If the requirement is less than the boiler’s capacity (e.g., thermostatic valves are closed), some heat returns from the LLH, signaling the boiler to decrease output or switch off.
- If the requirement exceeds the boiler’s capacity, increased pump suction signals the boiler to produce more heat.
Features of the Low Loss Header SHE 3”:
- Max flow: 24 m³/h
- Max power: 420 kW
- Connectors: 4 x 3" DN80 Flanges
- Nominal pressure: 6 bar
- Max temperature: 110°C
- Capacity: 27.5 l.
- Vent and drain valves included
Advantages for investors:
- Up to 30% longer boiler service life through protection from low return water temperatures
- Enhanced operational comfort via system desiltering and aeration
- Up to 30% longer pump service life due to smooth, undisturbed operation
- Faster boiler reactions to changing demands
- Cost savings of up to 50% compared to traditional 3- or 4-way valves
Advantages for installers:
- No need for complex system regulation, thanks to automatic flow management
- Reduced claims caused by air locking or improper operation
Variants Available:
- SHE – LLH: Power range from 40 to 420 kW
- SHE-OC: Insulated with polyprene shell, power from 40 to 156 kW (up to 420 kW can be insulated with ROCKWOOL upon request)
Customer satisfaction benefits from reliable, efficient heating operation with less maintenance and fewer issues.
Availability: Low stock
Dispatched within: 5 days
Low Loss Header, flanged 435kW, 4" insulated
Low Loss Header 420kW Low Loss Header with 4 flanged tapings DN16, insulated.
The whole technical info and sizes are available in the attached pictures.
Availability: Low stock
Dispatched within: 5 days
Set of the low loss header 100W, 1 1/2" insulated + 2 way manifold 1 1/2" + 3 way manifold 1 1/2" (5 circuits)
1 1/2" 70kW Coated Low Loss Header + 3 Way insulated connecting manifold 1 1/2" with female threaded tapings + 2 way connecting manifold 1 1/2" (5 circuits).
Availability: Low stock
Dispatched within: 48 hours
Set of the low loss header 115W, 2" insulated + 2 way manifold 2" + 3 way manifold 2" (5 circuits)
2" 115kW Coated Low Loss Header + 3 Way insulated connecting manifold 2" with female threaded tapings + 2 way connecting manifold 2" (5 circuits).
Availability: Low stock
Dispatched within: 48 hours
Set of the low loss header 156W, 2" insulated + 2 way manifold 2" + 3 way manifold 2" (5 circuits)
2" 156kW Coated Low Loss Header + 3 Way insulated connecting manifold 2" with female threaded tapings + 2 way connecting manifold 2" (5 circuits).
Availability: Low stock
Dispatched within: 48 hours
Set of the low loss header 40kW, 1" insulated + 2 way manifold + 3 way manifold 1"
1" 40kW Coated Low Loss Header + 3 Way insulated connecting manifold 1" with female threaded tapings + 2 way connecting manifold 1"
Availability: Low stock
Dispatched within: 48 hours
Set of the low loss header 70W, 1 1/4"" insulated + 2 way manifold 1 1/4" + 3 way manifold 1 1/4" (5 circuits)
1 1/4"" 70kW Coated Low Loss Header + 3 Way insulated connecting manifold 1 1/4" with female threaded tapings (865 mm) length + 2 way connecting manifold 1 1/4" (605mm) length
- 2 way insulated manifold length (F) - 605mm
- 3 way insulated manifold length (F) - 865mm
- 1 1/4 couplings for the low loss header and manifolds - 100mm each.
- distance between ciruit tapings (1 zone) 125mm
- distance between zone 135mm
Availability: Low stock
Dispatched within: 48 hours