Commercial, electric boiler 42kW, Silver Line LED control panel
- Basic, industrial LED series with greater power
- Increased components durability
- Main or alternative source of heat
- Equipped with 4 x PV ready ready funcionality
- Optional DHW control available
- Equipped with electronic pump and expansion vessel
- Build-in energy meter to cooperate with PV installation
- Perfect as an alternative source of heat in PV installations
- Adjustable boiler power to better cooperate with PV
- Max power adjustment for versions 15, 18 and 24kW
- Dedicated to cooperate with heat pumps
- Can operate in both sealed and air-vented heating system
- Electronic temperature setting - range 5-95°C
- Energy efficiency class D, spectrum A+++ to D
Availability: na wyczerpaniu
Dispatched within: 5 dni
Commercial, electric boiler 48kW, Silver Line LED control panel
- Basic, industrial LED series with greater power
- Increased components durability
- Main or alternative source of heat
- Equipped with 4 x PV ready ready funcionality
- Optional DHW control available
- Equipped with electronic pump and expansion vessel
- Build-in energy meter to cooperate with PV installation
- Perfect as an alternative source of heat in PV installations
- Adjustable boiler power to better cooperate with PV
- Max power adjustment for versions 15, 18 and 24kW
- Dedicated to cooperate with heat pumps
- Can operate in both sealed and air-vented heating system
- Electronic temperature setting - range 5-95°C
- Energy efficiency class D, spectrum A+++ to D
Availability: na wyczerpaniu
Dispatched within: 5 dni
Distribution Low Loss Header SKE 55kW, 3DC set + 3 x VRG 432 pump group with progressive valve and ARA actuator for radiators
Distribution Low Loss Header 55kW, 3 x VRG 432 pump group with progressive mixing valve and ARA actuator (underfloor heating, radiators),
This is the combination of a low loss header up to 55kW + 3 x VRG 432 mixing valve,
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 3 x VTA 372 pump group for underfloor heating
Distribution Low Loss Header 55kW, 3 x VRG 432 pump group with progressive mixing valve and ARA actuator (underfloor heating, radiators),
This is the combination of a low loss header up to 55kW + 3 x VTA372 mixing valve for underfloor heating
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 1 x universal pump group for Water cylinder, 2 x VRG 432 pump groups with progressive valve and ARA actuator for radiators
Distribution Low Loss Header 55kW, 3 zones + 1 x universal pump station (hot water cylinder), 2 x VRG 432 pump group with progresive mixing valve and ARA actuator (underfloor heating),
This is the combination of a low loss header up to 55kW and a connecting manifold with added 1 x universal pump station, 2 x VRG 432 mixing valves,
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 1 x universal pump group for Water cylinder, 2 x VTA 372 pump groups for underfloor heating
Distribution Low Loss Header 55kW, 3 zones + 1 x universal pump station (hot water cylinder), 2 x VTA 372 mixing valve (underfloor heating),
This is the combination of a low loss header up to 55kW and a connecting manifold with added 1 x universal pump station, 2 x VTA mixing valve for underfloor heating,
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 1 x universal pump group, 1 x VTA 372 pump group, 1 x VRG 432 with progressive valve and ARA actuator
Distribution Low Loss Header 55kW, 3 zones + 1 x universal pump station (hot water cylinder), 1 x VTA 372 mixing valve (underfloor heating), 1 x 432 VRG pump group with progressive valve and ARA actuator (underfloor heating, radiators)
This is the combination of a low loss header up to 55kW and a connecting manifold with added 1 x universal pump station, 1 x VTA mixing valve for underfloor heating, 1 x VRG 432 pump group for radiators.
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 2 x universal pump group for water cylinder, 1 x VRG 432 pump group with progresive valve and ARA actuator for radiators
Distribution Low Loss Header 55kW, 3 zones + 2 x universal pump stations (hot water cylinder), 1 x VRG 432 pump group with progressive mixing valve and ARA actuator (underfloor heating, radiators),
This is the combination of a low loss header up to 55kW and a connecting manifold with added 2 x universal pump stations, 1 x VRG 432 mixing valve,
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 3DC set + 3 x universal pump groups.
Distribution Low Loss Header 55kW, 3 zones + 3 x universal pump stations
This is the combination of a low loss header up to 55kW and a connecting manifold with added 3 x universal pump stations. The set presented may be perfect for the heating systems where no mixing valves are required. It also can be used for 3 circuits with hot water cylinders.
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 35kW, 1" insulated
Condensing Distribution Low Loss Header 1" 35kW - HORIZONTAL/VERTICAL
This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.
Availability: tymczasowo niedostępny
£225.00
Distribution Low Loss Header SKE 40kW, 1" insulated
Distribution Low Loss Header 1" 40kW - HORIZONTAL/VERTICAL
This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.
Hydraulic Coupling-Collectors SKE
SKE coupling-collectors are available in standard and Condens (DC) versions. The Condens version is equipped with a patented flow director. The Inox director maintains high efficiency of condensing boilers or heat pumps. The Inox director allows for alternating connection of pump groups with a spacing of 125mm. A version for heating circuits DN32 is also available. The standard version (2D+) offers limited possibilities for connecting pump groups. Universal construction (adaptation kit) enables installation within a 360° range. Connection of two, three, or four (4DC) pump groups is possible. Expansion of SKE 2DC+ for an additional heating circuit (expansion kit, only DN25) is possible. SKE 2DC+ are part of ready-made sets with pump groups – Kompania and Kompania PRO. Products are insulated with EPP molds.
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 55kW, 1" insulated
Condensing Distribution Low Loss Header 1" 55kW - HORIZONTAL/VERTICAL
This low loss header has 4 x 1" tapings on 1 side and 2 x 1" tapings on the opposite side.
Availability: duża ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 70kW, 1" insulated
Distribution Low Loss Header 1" 70kW - HORIZONTAL/VERTICAL
This low loss header has 4 x 1" tapings on 1 side and 2 x 1 1/4" tapings on the opposite side.
Hydraulic Coupling-Collectors SKE
SKE coupling-collectors are available in standard and Condens (DC) versions. The Condens version is equipped with a patented flow director. The Inox director maintains high efficiency of condensing boilers or heat pumps. The Inox director allows for alternating connection of pump groups with a spacing of 125mm. A version for heating circuits DN32 is also available. The standard version (2D+) offers limited possibilities for connecting pump groups. Universal construction (adaptation kit) enables installation within a 360° range. Connection of two, three, or four (4DC) pump groups is possible. Expansion of SKE 2DC+ for an additional heating circuit (expansion kit, only DN25) is possible. SKE 2DC+ are part of ready-made sets with pump groups – Kompania and Kompania PRO. Products are insulated with EPP molds.
Availability: średnia ilość
Dispatched within: 48 godzin
Distribution Low Loss Header SKE 90kW, 2DC+ insulated
Condensing Distribution Low Loss Header 90kW - HORIZONTAL/VERTICAL
This low loss header has 4 x 1" tapings on 1 side and 2 x 1 1/4" tapings on the opposite side.
Availability: na wyczerpaniu
Dispatched within: 48 godzin
Distribution Manifold 1 1/2" - 2 way, for low loss headers 100kW & 125kW
Distribution Manifolds are in with low loss headers to distribute liquids further to a heating system.
This particular products helps distribute liquids from low loss header to a heating system.
- 2 circuits = 4 x 1 1/2" male threaded tapings
- main tapings connect the header are 1 1/2" male threaded
Availability: na wyczerpaniu
Dispatched within: 48 godzin
Distribution Manifold 1 1/2" - 3 way, for low loss headers 100kW & 125kW (1)
Distribution Manifolds are in with low loss headers to distribute liquids further to a heating system.
This particular products helps distribute liquids from low loss header to a heating system.
- 3 circuits = 6 x 1 1/2" male threaded tapings
- main tapings connect the header are 1 1/2" male threaded
Availability: na wyczerpaniu
Dispatched within: 48 godzin
Distribution Manifold 1 1/4" - 2 way, for low loss headers 70kW & 90kW
Distribution Manifolds are in with low loss headers to distribute liquids further to a heating system.
This particular products helps distribute liquids from low loss header to a heating system.
- 2 circuits = 4 x 1 1/4" male threaded tapings
- main tapings connect the header are 1 1/4" female threaded
Availability: na wyczerpaniu
Dispatched within: 48 godzin
Distribution Manifold 1 1/4" - 3 way, for low loss headers 70kW & 90kW
Distribution Manifolds are in with low loss headers to distribute liquids further to a heating system.
This particular products helps distribute liquids from low loss header to a heating system.
- 2 circuits = 4 x 1 1/4" male threaded tapings
- main tapings connect the header are 1 1/4" female threaded
Availability: na wyczerpaniu
Dispatched within: 48 godzin