Price
-
from
to
Low Loss Header 8 x 1" tapings and 2 x 1" tapings SKE 90 4DC
Condensing Distribution Low Loss Header 90kW - HORIZONTAL/VERTICAL
This low loss header has 8 x 1" tapings on 1 side and 4 x 1 1/4" tapings on the opposite side.
There's a possibility of the header extension by 2 tapings.
Distribution low loss header SKE Condens
Patent P.421240 Flow control
The most technically advanced Distribution low loss header SKE Condens in the UK.
• maintains high efficiency of the condensing boiler
• guarantees even hot water consumption by pump groups
• allows installation of several pump groups with any mixing valve
• INOX flow control valve
• for use with 1, 2,3 or 4 heat sources
SKE Distribution Low-Loss Headers (Hydraulic Balancers) – Basic Versions
Function and Application
The SKE distribution low-loss header, also known as a hydraulic balancer, is designed to hydraulically separate the boiler circuit from the heating circuit. It is primarily used in medium- and high-power heating systems (starting from 25 kW and typically from 40 kW upward), which may include:
-
One or more boilers (solid fuel, gas condensing, or heat pump-based)
-
Multiple heating zones or circuits (e.g. underfloor heating, radiator heating, and domestic hot water (DHW))
In such complex systems, the SKE eliminates the need for manual flow balancing between pumps. It allows each circuit to operate independently and without interference, ensuring optimal pump performance and stable hydraulic conditions.
Key Features
-
Hydraulic Separation: Enables independent operation of boiler and heating circuits, preventing mutual pump interference.
-
Integrated Desilter and Air Vent: Enhances system reliability by removing sludge and air from the circuit.
-
SMART Magnetic Separator: A built-in neodymium magnet captures fine magnetic particles, preventing corrosion and rust caused by circulating debris.
-
Boiler Protection: Prevents low return water temperature to solid fuel boilers (avoiding condensation and corrosion).
-
Flexible Installation: The unit can be installed in any orientation, adapting to site-specific requirements.
Operating Scenarios
-
Heat Demand = Boiler Output
The system operates under equilibrium. Boiler output matches the heating circuit demand. -
Heat Demand < Boiler Output
When thermostatic valves (e.g. on radiators) begin closing, excess heat circulates back through the hydraulic balancer. This signals the boiler to reduce output or shut down. -
Heat Demand > Boiler Output
Increased suction from the heating circuit through the balancer signals the boiler to increase power to meet demand.
Available Models and Applications
| Model | Key Features | Recommended For |
|---|---|---|
| SKE 40 / 40 2D+ / 40 3D / 40 2K | Includes boiler protection against low return temps | Solid fuel boiler systems |
| SKE 55 2DC / 55 3DC | Optimized for high efficiency | Condensing gas boilers & heat pumps |
Why Choose the SKE Hydraulic Balancer?
-
Simplifies multi-circuit system design and commissioning
-
Enhances system longevity and efficiency
-
Reduces maintenance through built-in magnetic filtration and air removal
-
Compatible with modern high-efficiency boilers and heat pumps
-
Modular models available for varying system sizes and configurations
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header 8 x 1" tapings and 2 x 1" tapings SKE 90 4DC (1)
Condensing Distribution Low Loss Header 55kW - HORIZONTAL/VERTICAL
This low loss header has 8 x 1" tapings on 1 side and 4 x 1" tapings on the opposite side.
There's a possibility of the header extension by 2 tapings.
Distribution low loss header SKE Condens
Patent P.421240 Flow control
The most technically advanced Distribution low loss header SKE Condens in the UK.
• maintains high efficiency of the condensing boiler
• guarantees even hot water consumption by pump groups
• allows installation of several pump groups with any mixing valve
• INOX flow control valve
• for use with 1, 2,3 or 4 heat sources
SKE Distribution Low-Loss Headers (Hydraulic Balancers) – Basic Versions
Function and Application
The SKE distribution low-loss header, also known as a hydraulic balancer, is designed to hydraulically separate the boiler circuit from the heating circuit. It is primarily used in medium- and high-power heating systems (starting from 25 kW and typically from 40 kW upward), which may include:
-
One or more boilers (solid fuel, gas condensing, or heat pump-based)
-
Multiple heating zones or circuits (e.g. underfloor heating, radiator heating, and domestic hot water (DHW))
In such complex systems, the SKE eliminates the need for manual flow balancing between pumps. It allows each circuit to operate independently and without interference, ensuring optimal pump performance and stable hydraulic conditions.
Key Features
-
Hydraulic Separation: Enables independent operation of boiler and heating circuits, preventing mutual pump interference.
-
Integrated Desilter and Air Vent: Enhances system reliability by removing sludge and air from the circuit.
-
SMART Magnetic Separator: A built-in neodymium magnet captures fine magnetic particles, preventing corrosion and rust caused by circulating debris.
-
Boiler Protection: Prevents low return water temperature to solid fuel boilers (avoiding condensation and corrosion).
-
Flexible Installation: The unit can be installed in any orientation, adapting to site-specific requirements.
Operating Scenarios
-
Heat Demand = Boiler Output
The system operates under equilibrium. Boiler output matches the heating circuit demand. -
Heat Demand < Boiler Output
When thermostatic valves (e.g. on radiators) begin closing, excess heat circulates back through the hydraulic balancer. This signals the boiler to reduce output or shut down. -
Heat Demand > Boiler Output
Increased suction from the heating circuit through the balancer signals the boiler to increase power to meet demand.
Available Models and Applications
| Model | Key Features | Recommended For |
|---|---|---|
| SKE 40 / 40 2D+ / 40 3D / 40 2K | Includes boiler protection against low return temps | Solid fuel boiler systems |
| SKE 55 2DC / 55 3DC | Optimized for high efficiency | Condensing gas boilers & heat pumps |
Why Choose the SKE Hydraulic Balancer?
-
Simplifies multi-circuit system design and commissioning
-
Enhances system longevity and efficiency
-
Reduces maintenance through built-in magnetic filtration and air removal
-
Compatible with modern high-efficiency boilers and heat pumps
-
Modular models available for varying system sizes and configurations
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header PRO 2K up to 70kW, PRO - 1 1/4" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 135kW, 4 x 1 1/2" insulated CONDENSING
Low Loss Header SHE 135kW, 4 x 1 1/2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 150kW, 4 x 2" insulated CONDENSING
Low Loss Header SHE 150kW, 4 x 2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 210kW, 4 x 2" insulated CONDENSING
Low Loss Header SHE 210kW, 4 x 2" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 35kW, 1" insulated CONDENSING
Low Loss Header SHE 35kW, 4 x 1" male threaded tapings
Availability: Low stock
Dispatched within: 5 days
Low Loss Header SHE 55kW, 4 x 1" insulated CONDENSING
Low Loss Header SHE 55kW, 4 x 1" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header SHE 90kW, 4 x 1 1/4" insulated CONDENSING
Low Loss Header SHE 90kW, 4 x 1 1/4" male threaded tapings, CONDENSING
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header up to 100kW, 2K PRO - 1 1/2" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header up to 156kW, 2K PRO - 2" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header, flanged 225kW, 2.5" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Low-Loss Header, also called a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium- to high-power setups (from 25 kW up to 420 kW). It’s used with one or more boilers and supports various heating circuits like floor heating, radiators, and hot utility water.
Key Functions and Benefits:
- Flow Separation: Automatically divides flow, allowing boiler and system to operate independently without manual balancing.
- Additional Features: Equipped with a desilter and air vent, which aid in system cleaning and removing air, enhancing efficiency.
- Protection: Prevents low-temperature corrosion by maintaining appropriate return water temperatures.
Operational Modes:
- Heat demand = boiler output: System operates normally.
- Heat demand < boiler output (e.g., thermostatic valves closed): Part of the heat returns, signaling the boiler to decrease or switch off.
- Heat demand > boiler output: Pump suction increases, prompting the boiler to produce more heat.
Equipment Details:
Low Loss Header SHE 2.5" Flanges
- Max flow: 24 m³/h
- Max power: 420 kW
- Connectors: 4 x 2.5" flanges
- Nominal pressure: 10 bar
- Max temperature: 110°C
- Capacity: 19.7 liters
Advantages for Investors:
- Up to 30% longer boiler lifespan due to protection from low return water temperatures
- Increased comfort through system desiltering and aeration
- Up to 30% longer pump operation life
- Faster boiler response
- Up to 50% cost savings versus 3- or 4-way valves
- No system regulation needed
- Fewer system claims caused by air locking or improper operation
Variants Available:
- SHE – LLH: Power range from 40 to 750 kW
- SHE-OC: Insulated with PUR foam and leatherette; power from 40 to 156 kW (larger units up to 750 kW can be insulated with ROCKWOOL if requested)
- Summary:
This hydraulic balancer ensures efficient, reliable operation of heating systems, reduces maintenance, and prolongs equipment lifespan—offering long-term savings and peace of mind for system owners.
Availability: Low stock
Dispatched within: 48 hours
Low Loss Header, flanged 420kW, 3" insulated
ELTERM products are made of high-quality mild steel, manufactured in accordance with the highest testing and certification standards. All products are designed and welded to meet the strictest quality requirements.
.Our factory has over 30 years of experience in the heating industry. Throughout these years, we have developed and invented numerous products that have become widely used. We distribute these solutions across Europe and other continents, ensuring quality and innovation in every application.
Please note: We (Culm Stores Distribution Elterm Ltd) do not offer any products made of so-called "galvanized stainless steel." Our products are made from genuine materials that meet rigorous EU & BS safety and quality standards.
Low-Loss Header, also known as a Hydraulic Balancer, is designed to separate the boiler’s circulation from the heating system, suitable for medium to high-power systems (25 kW and above, ideal for an average house). It is used in setups with one or more boilers and various heating circuits, such as floor heating, radiators, or hot utility water. The LLH automatically manages flow separation, eliminating the need for manual balancing of pump flows. Its construction includes a desilter and air vent, offering additional benefits of system cleaning and air removal while protecting the boiler from low-temperature corrosion of the return water.
Operational Modes:
- When the heat requirement equals the boiler’s power, the system operates in balance.
- If the requirement is less than the boiler’s capacity (e.g., thermostatic valves are closed), some heat returns from the LLH, signaling the boiler to decrease output or switch off.
- If the requirement exceeds the boiler’s capacity, increased pump suction signals the boiler to produce more heat.
Features of the Low Loss Header SHE 3”:
- Max flow: 24 m³/h
- Max power: 420 kW
- Connectors: 4 x 3" DN80 Flanges
- Nominal pressure: 6 bar
- Max temperature: 110°C
- Capacity: 27.5 l.
- Vent and drain valves included
Advantages for investors:
- Up to 30% longer boiler service life through protection from low return water temperatures
- Enhanced operational comfort via system desiltering and aeration
- Up to 30% longer pump service life due to smooth, undisturbed operation
- Faster boiler reactions to changing demands
- Cost savings of up to 50% compared to traditional 3- or 4-way valves
Advantages for installers:
- No need for complex system regulation, thanks to automatic flow management
- Reduced claims caused by air locking or improper operation
Variants Available:
- SHE – LLH: Power range from 40 to 420 kW
- SHE-OC: Insulated with polyprene shell, power from 40 to 156 kW (up to 420 kW can be insulated with ROCKWOOL upon request)
Customer satisfaction benefits from reliable, efficient heating operation with less maintenance and fewer issues.
Availability: Low stock
Dispatched within: 5 days
Low Loss Header, flanged 435kW, 4" insulated
Low Loss Header 420kW Low Loss Header with 4 flanged tapings DN16, insulated.
The whole technical info and sizes are available in the attached pictures.
Availability: Low stock
Dispatched within: 5 days
Plate Heat Exchanger BA 12 -30 65kW with 3/4" tapings + insulation (no fixing brackets)
Stainless steel plate heat exchanger - 12 plates, 65kW 3/4" tappings + insulation + set of 3/4" brackets
Availability: Low stock
Dispatched within: 48 hours
Plate heat exchanger Ba 23-20 90kW 3/4" tapings + insulation (no brackets)
INOX (Stainless steel) Plate Heat Exchanger BA 23-20, 90kW, 3/4" tapings + brackets and insulation
Availability: Low stock
Dispatched within: 48 hours